BUOYANCY VERIFICATION          
The app returns buoyancy verification of underground pipes subject to tablewater conditions    
REMARK: sheet returns valid data only if  H ≥ Hf      
Pipe Type
 Pipe DN/OD DN (mm)
SN (only for UNI EN 13476 pipes) SN (KPa)
DR SDR (  )
Pipe Internal Diameter Di (mm)    
Pipe meterweight (calculated upon emin) Pp (Kg/m)    
Backfill soil type    
   
Backfill soil density gs (Kg/m3)    
Density of fluid in watertable gw (Kg/m3)    
 Installation depth H (m)    
Tablewater depth Hf (m)    
Linear weight of soil above tablewater Ps1 (Kg/m)    
Linear weight of soil below tablewater Ps2 (Kg/m)    
Linear total weight (soil + pipe) Ptot (Kg/m)    
 Buoyancy force SA (Kg/m)    
Verification fo buoyancy     SA<Ptot
Safety coeff for buoyancy
(  )